На главную страницу Контакты Ru  |  En

Environment Conditions for Oracle Database Appliance

Operating temperature: 5° C to 35° C (41° F to 95° F) at sea level; 5° C to 31° C (41° F to 88° F) at altitude

Nonoperating temperature: –40° C to 70° C (–40° F to 158° F)

Operating relative humidity: 10% – 90%, noncondensing

Nonoperating relative humidity: 93% relative humidity, noncondensing

Operating altitude: up to 3,048 m; maximum ambient temperature is derated by 1° C per 300 m above 900 m

Nonoperating altitude: up to 12,000 m

Acoustic noise: 7.8 B operating, 7.1 B idling - (LwAd: 1 B=10 dB)

Airflow: 130 CFM typical, 250 CFM max

Regulations

Safety: UL/CSA 60950-1 2nd Ed, EN60950-1:2006 2nd Ed +A11:2009, IEC60950-1:2005 CB Scheme with all country differences

RFI/EMI: FCC CFR 47 Part 15 Subpart B Class A, EN 55022:2006+A1:2007 Class A, EN 61000-3-2:2006, EN 61000-3-3:1995+A1:2001+A2:2002, ETSI EN 300 386 V1.4.1 (2008)

Immunity: EN 55024:1998+A1:2001:+A2:2003

Certifications

Safety: cTUVus, CE, BSMI, GOST R, S-Mark, CCC

EMC: CE, FCC, VCCI, ICES, C-Tick, KCC, GOST R, BSMI Class A

Other: complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)

Dimensions and Weight

Height: 175.1 mm (6.9 in.)

Width: 482.6 mm (19.0 in.); without mounting ears: 437 mm (17.2 in.)

Depth (to fan module handles and latches): 782.0 mm (30.8 in.)

Weight: 72.6 kg (160 lb.)

Mounting Options

Rack-mounting slide rail kit (included)